Sign In | Join Free | My himfr.com
Home > VCB Circuit Breaker >

Solid Sealed Pole Vacuum VCB Circuit Breaker 12KV For Transformer Substation

    Buy cheap Solid Sealed Pole Vacuum VCB Circuit Breaker 12KV For Transformer Substation from wholesalers
     
    Buy cheap Solid Sealed Pole Vacuum VCB Circuit Breaker 12KV For Transformer Substation from wholesalers
    • Buy cheap Solid Sealed Pole Vacuum VCB Circuit Breaker 12KV For Transformer Substation from wholesalers

    Solid Sealed Pole Vacuum VCB Circuit Breaker 12KV For Transformer Substation

    Ask Lasest Price
    Brand Name : KNKONG
    Model Number : VS1-12
    Certification : CB,ISO,IEC
    Price :
    Payment Terms : L/C, T/T, Western Union
    Supply Ability : 1000 Unit per month
    Delivery Time : 15 working days
    • Product Details
    • Company Profile

    Solid Sealed Pole Vacuum VCB Circuit Breaker 12KV For Transformer Substation

    VCB solid-sealed pole vacuum circuit breaker 2000A 12KV for transformer substation using

    Voltage: 12-24KV

    Current: Max 2000A

    Breaking current: 20KA

    Type: withdrawable/Fixed


    Product overview

    VS1-series solid-sealed pole vacuum circuit breaker is suitable for 12kV, 24KV, three-phase alternating current frequency of 50, 60Hz indoor switchgear KYN28-12 (24) central and fixed switchgear operation together. The VS1 vacuum circuit breaker can be fixedly installed or combined with a trolley.


    Special service condition

    The special operating conditions are negotiated in advance by the manufacturer and the user (the manufacturer must consult the user in advance for each special operating condition) such as:
    -Whether the site altitude exceeds 1000m (or need to order a prototype circuit breaker).
    -Allows reducing the dielectric strength of the air.
    -Corresponding insulation requirements.
    -Situations where the ambient temperature rises.
    -Whether the current carrying capacity is reduced.
    -Is it necessary to provide additional ventilation for heat dissipation
    Other precautions should be negotiated with the manufacturer according to section 2.2 of IEC 62271-1

    Technical Parameters

    No.ItemUnitParameter
    1Rated voltageKV12
    2Rated frequencyHz50/60
    3

    Rated insulation level

    1min power frequency withstand voltage(r. m. s)

    KV

    42(phase-to-phase, phase-to-earth)

    48(across the isolating distance)

    Lighting impulse withstand voltage (peak)

    75(phase-to-phase, phase-to-earth)

    85(across the isolating distance)


    4


    Rated current


    A

    63063012501600
    1250125016002000
    20002500
    25003150
    4000
    5Rated short-circuit breaking current

    KA

    202531.540
    6Rated short-time withstand current202531.540
    7Rated short-circuit marking current506380100
    8Rated peak withstand current506380100
    9Rated duration of short-circuits4
    10Rated operating sequenceO-0.3s-O/C-180s-O/C
    11Breaking times of rated short-circuit currentTimes30/20 times(40KA)
    12Mechanical enduranceOps20000
    13Rated single capacitor bank breaking current

    A

    630
    14Rated back-to-back capacitor bank breaking current400
    15Double-earth fault breaking current27.4
    16Allowable maximum contact erosion

    mm

    3
    17Clearance between open contacts10±1
    18Over stroke3.5±0.5
    19Non-simultaneity of 3-phase opening and closing

    ms


    ≤2
    20Bounce duration of contact closing≤2
    21Average breaking speed (instant breaking 6mm)

    m/s


    1.1±0.2
    22Average making speed0.8±0.2
    23Making time

    ms


    ≤100
    24Breaking time≤50

    25


    Resistance of each phase main circuit


    μ Ω

    630A≤50
    1250A≤45
    1600A~2000A≤35
    ≥2500A≤25
    26Contact breaking bounce amplitudemm≤2

    27

    Rated operating voltageRated operating voltage(V)AC/DC

    V

    24*110220
    Scope of normal operation voltageOpening:65%-120% rated voltage, in case the voltage is lower than 30% rated voltage, opening operation is not allowed
    28Rated voltage of energy storage motorVAC110/220,DC110/220
    29Energy storage timeS≤15

    Operation safety

    VS1 vacuum circuit breaker has anti-misoperation lockout protection, realizes the "five guarantee" interlock function in the switch cabinet, avoids misoperation, and protects the personal safety of operators to the greatest extent.
    Only when the VS1 vacuum circuit breaker and the grounding switch are in the off position at the same time, can the trolley roll from the "detection position" to the "service position".
    The VS1 vacuum circuit breaker can only be closed in the "service/test" position.
    When the VS1 vacuum circuit breaker is closed, the trolley cannot be moved in or out, only when the circuit breaker is in the off position.
    The VS1 vacuum circuit breaker in the closed position cannot be shaken out from the "service position" to the "detection position".
    The circuit breaker cannot be closed when pushed in.
    When the circuit breaker is closed, if the closing signal is not released in time, the internal anti-trip control circuit will cut off the closing circuit to prevent multiple reclosing (optional).
    Note: If the customer chooses electric closing and locking instead of manual closing and locking, the circuit breaker will not be closed when the secondary circuit cannot provide power or the power provided cannot meet the normal operation of the locking electromagnet (optional).

    Quality Solid Sealed Pole Vacuum VCB Circuit Breaker 12KV For Transformer Substation for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Knkong Electric Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)