    Brand Name : KNKONG
    Model Number : VS1-12
    Certification : CB,ISO,IEC
    Payment Terms : L/C, T/T, Western Union
    Supply Ability : 1000 Unit per month
    Delivery Time : 15 working days
    • Product Details
    • Company Profile

    12KV Solid Sealed Pole VCB Circuit Breaker 25KA Explosion Proof

    Solid sealed pole vacuum circuit breaker 12KV for indoor electric panel

    Voltage: 12-24KV

    Current: Max 2000A

    Breaking current: 20KA

    Type: withdrawable/Fixed


    Product overview

    Vacuum circuit breaker: It is a new type of high-voltage circuit breaker developed in the 1960s (for example, the picture at the beginning of this article is ZN28-12 indoor high-voltage vacuum circuit breaker), which uses vacuum to extinguish arcs. Its advantages are small size, light weight, fast action, fireproof and explosion-proof, low noise and so on. At present, there is a trend to replace other circuit breakers, mainly used in substations below 35KV and places requiring frequent operations in industrial and mining enterprises.


    Technical Parameters

    No.ItemUnitParameter
    1Rated voltageKV12
    2Rated frequencyHz50/60
    3

    Rated insulation level

    1min power frequency withstand voltage(r. m. s)

    KV

    42(phase-to-phase, phase-to-earth)

    48(across the isolating distance)

    Lighting impulse withstand voltage (peak)

    75(phase-to-phase, phase-to-earth)

    85(across the isolating distance)


    4


    Rated current


    A

    63063012501600
    1250125016002000
    20002500
    25003150
    4000
    5Rated short-circuit breaking current

    KA

    202531.540
    6Rated short-time withstand current202531.540
    7Rated short-circuit marking current506380100
    8Rated peak withstand current506380100
    9Rated duration of short-circuits4
    10Rated operating sequenceO-0.3s-O/C-180s-O/C
    11Breaking times of rated short-circuit currentTimes30/20 times(40KA)
    12Mechanical enduranceOps20000
    13Rated single capacitor bank breaking current

    A

    630
    14Rated back-to-back capacitor bank breaking current400
    15Double-earth fault breaking current27.4
    16Allowable maximum contact erosion

    mm

    3
    17Clearance between open contacts10±1
    18Over stroke3.5±0.5
    19Non-simultaneity of 3-phase opening and closing

    ms


    ≤2
    20Bounce duration of contact closing≤2
    21Average breaking speed (instant breaking 6mm)

    m/s


    1.1±0.2
    22Average making speed0.8±0.2
    23Making time

    ms


    ≤100
    24Breaking time≤50

    25


    Resistance of each phase main circuit


    μ Ω

    630A≤50
    1250A≤45
    1600A~2000A≤35
    ≥2500A≤25
    26Contact breaking bounce amplitudemm≤2

    27

    Rated operating voltageRated operating voltage(V)AC/DC

    V

    24*110220
    Scope of normal operation voltageOpening:65%-120% rated voltage, in case the voltage is lower than 30% rated voltage, opening operation is not allowed
    28Rated voltage of energy storage motorVAC110/220,DC110/220
    29Energy storage timeS≤15

    Quality 12KV Solid Sealed Pole VCB Circuit Breaker 25KA Explosion Proof for sale