Sign In | Join Free | My himfr.com
Home > Electric Power Transformer >

ISO IEC GB 10KV/0.4KV 800KVA 3 Phase Power Transformer

    Buy cheap ISO IEC GB 10KV/0.4KV 800KVA 3 Phase Power Transformer from wholesalers
     
    Buy cheap ISO IEC GB 10KV/0.4KV 800KVA 3 Phase Power Transformer from wholesalers
    • Buy cheap ISO IEC GB 10KV/0.4KV 800KVA 3 Phase Power Transformer from wholesalers

    ISO IEC GB 10KV/0.4KV 800KVA 3 Phase Power Transformer

    Ask Lasest Price
    Brand Name : Knkong
    Model Number : S11
    Certification : ISO IEC CB
    Price : USD 1000-3000
    Payment Terms : L/C, T/T
    Supply Ability : 100 Unit per month
    Delivery Time : 15 days
    • Product Details
    • Company Profile

    ISO IEC GB 10KV/0.4KV 800KVA 3 Phase Power Transformer

    10/0.4KV 3-phases oil type power transformer 30-2500KVA ISO IEC GB

    Product Introduction

    The oil-immersed transformer is one of the important pieces of equipment in the power supply and distribution system of industrial and mining enterprises and civil buildings. It reduces the 10(6)kV or 35kV network voltage to the 230/400V bus voltage used by the user. This type of product is suitable for AC 50 (60) Hz, three-phase maximum rated capacity 2500kVA (single-phase maximum rated capacity 833kVA, single-phase transformer is generally not recommended), can be used indoors (outdoor), when the capacity is 315kVA and below Can be installed on a pole, the ambient temperature is not higher than 40℃, not lower than -25℃, the highest daily average temperature is 30℃, the highest annual average temperature is 20℃, the relative humidity does not exceed 90% (ambient temperature 25℃), altitude No more than 1000m. If it is inconsistent with the above conditions of use, appropriate quota adjustments should be made in accordance with the relevant provisions of GB6450-86.

    Features
    1. The transformer iron core greatly reduces the no-load loss and no-load current, and the iron core is bound to ensure the tightness of the iron core and reduce noise.
    2. The high and low voltage windings are made of oxygen-free copper, and the low voltage windings of 500kVA and below adopt a double-layer cylindrical structure. 630kVA and above adopt double-spiral or quad-spiral structure, and high-voltage winding adopts multi-layer cylindrical structure.
    3. The transformer connection group uses Dyn11 to reduce the impact of harmonics on the power grid and improve the quality of power supply.
    4. The transformer is a fully sealed structure, which prolongs the service life, does not need to hang the core and is free of maintenance.
    5. The measured noise value is lower than the standard.
    After this series of transformers are transported normally, the relevant parts can be installed without core checking, and the acceptance test can be carried out, and they can be put into operation after being qualified.

    Product Standards

    GB1094.1-2013
    GB1094.2-2013
    GB1094.3-2003
    GB1094.5-2008
    GB/T1094.10-2003
    GB/T25446-2010


    Performance characteristics
    a. The low-voltage windings of oil-immersed transformers generally adopt a cylindrical structure with copper foil around the shaft, except for the small-capacity copper wires; the high-voltage winding adopts a multi-layer cylindrical structure to balance the ampere-turn distribution of the winding and cause leakage. Small, high mechanical strength, strong short-circuit resistance.
    b. The iron core and the winding are each adopted with fastening measures. The fastening parts such as the height of the device and the low-voltage lead are equipped with self-locking lock nuts, and the non-suspending structure is adopted to withstand the shock of transportation.
    c. The coil and iron core are vacuum dried, and the transformer oil is vacuum filtered and oiled to minimize the moisture inside the transformer.
    d. The oil tank adopts corrugated sheet, which has a breathing function to compensate for the volume change of the oil caused by temperature changes, so this product does not have an oil conservator, which obviously reduces the height of the transformer.
    e. Because the corrugated sheet replaces the oil conservator, the transformer oil is isolated from the outside world, which effectively prevents the entry of oxygen and moisture, which leads to a decrease in insulation performance.
    f. According to the above five points of performance, it is ensured that the oil-immersed transformer does not need to be changed during normal operation, which greatly reduces the maintenance cost of the transformer and prolongs the service life of the transformer.

    10KV S11 Oil Transformer main technical data

    Rated Capacity
    (KVA)
    High
    voltage
    (KV)
    Tapping
    Range
    Low
    voltage
    (KV)
    Frequency
    (Hz)
    Connection
    Symbol
    No-load loss
    (W)
    load loss
    (W)
    No-load Current
    (%)
    Noise level
    (dB)
    Short-circuit
    impedance (%)
    Gauge
    A x B
    (mm x mm)
    Dimensions
    L*W*H (mm)
    Weight (KG)
    306
    6.3
    6.6
    10
    10.5
    11
    ±5%
    ±2X 2. 5%
    0.450
    1. yn11
    2. Y, ynO
    1006302.3444400770X545X890260
    501309102.044400790X560X920320
    8018013101.948400850X635X980420
    10020015801.848550865X685X990470
    16028023101.6495501120X740X1050610
    20034027301.5515501235X825X1080750
    25040032001.4515501275X860X1100850
    31548038301.4535501300X870X1170960
    40057045201.3536601395X960X11901160
    50068054101.2546601530X1080X12301340
    63081062001.1544.56601660X1180X13001660
    80098075001.0578201740X1255X14002100
    10001150103001.0578201780X1320X14902400
    12501360120000.9598201855X1345X15802850
    16001640145000.8598201960X1415X17003430

    10KV-S13/14 Oil Transformer main technical data

    Rated Capacity
    (KVA)
    High
    voltage
    (KV)
    Tapping
    Range
    Low
    voltage
    (KV)
    Frequency
    (Hz)
    Connection
    Symbol
    No-load loss
    (W)
    load loss
    (W)
    No-load Current
    (%)
    Noise level
    (dB)
    Short-circuit
    impedance (%)
    Gauge
    A x B
    (mm x mm)

    Dimensions

    L*W*H (mm)

    Weight (KG)
    S13S14S13S14
    30

    6

    6.3

    6.6

    10

    10.5

    11

    ±5%

    ±2X 2.5%

    0.450D, yn11 Y. ynO8080630/600505/4801.4504400X40C1005X670X960280
    50100100910/870730/6951.250400 X 40C1005X670X990390
    801301301310/12501050/10000.9752400X40C1060 X 715X1040495
    1001501501580/15001265/12000.9752550X55C1075X735X1060600
    1251701701890/18001510/14400.8454550X55C1110X750X1100690
    1602002002310/22001850/17600.8454550X55C1140X780X1130780
    2002402402730/26002185/20800.7456550X55C1210X815X1150908
    2502902903200/3052560/24400.6456550X55C1290X885X11901043
    3153403403830/36503065/29200.6458550X55C1300X880X12301190
    4004104104520/43003615/34400.5458660 X 66C1410X975X13001430
    5004804805410/51504330/41200.5460660X66C1465 X 980X13901648
    630570570620049600.54604.5660X66C1560X1050X14102027
    800700700750060000.4862820X82C1700X1160X14802500
    10008308301030082400.4262820X82C1790X1280X15202700
    12509709701200096000.3665820X82C1890X1360X16003280
    16001170117014500116000.3669820X82C1970X1430X1700

    3500

    Quality ISO IEC GB 10KV/0.4KV 800KVA 3 Phase Power Transformer for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Knkong Electric Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)